Skip to content

Configure timeout

This page describes the global timeout configuration for Ingress Nginx and the timeout configuration available for specific Ingress resources.

Configure the global timeout

The global timeout for Ingress Nginx can be configured using the following configuration options .

option's name description default
proxy-connect-timeout Set the timeout for establishing a connection with a proxied server. The default is 5s, but it cannot usually exceed 75s
proxy-read-timeout Set the timeout for reading a response from the proxied server. This timeout is only set between two consecutive read operations, not for the entire transmission of the response. 60s
proxy-send-timeout Set the timeout for transmitting a request to the proxied server. This timeout is only set between two consecutive write operations, not for the entire transmission of the request. 60s
proxy-stream-next-upstream-timeout Limit the time allowed to pass the connection to the next server. The default is 600s, and 0s will disable this limit.
proxy-stream-timeout Set the timeout between two consecutive read or write operations on a client or proxy server connection. If no data is transferred within this time, the connection will be closed. 600s
upstream-keepalive-timeout Set a timeout during which a keep-alive client connection will stay open. 60
worker-shutdown-timeout Set a graceful shutdown timeout. 240s
proxy-protocol-header-timeout Set the timeout for receiving proxy protocol headers. The default of 5 seconds prevents TLS direct handlers from waiting indefinitely for a broken connection. 5s
ssl-session-timeout Sets the valid time for session parameters in the SSL session cache. The session expiration time is relative to the creation time. Each session cache will take up about 0.25MB. 10m
client-body-timeout Set the timeout for reading a client request body. 60s
client-header-timeout Defines the timeout for reading a client request header. 60s

Configure custom timeout

The following are custom timeout configurations, and associated parameter configurations, such as the number of retries, etc:

option's name description
nginx.ingress.kubernetes.io/proxy-connect-timeout Set the timeout for establishing a connection with a proxied server.
nginx.ingress.kubernetes.io/proxy-send-timeout Set the timeout for transmitting a request to the proxied server.
nginx.ingress.kubernetes.io/proxy-read-timeout Set the timeout for reading a response from the proxied server.
nginx.ingress.kubernetes.io/proxy-next-upstream Set retry policies or retry conditions with multiple combinations separated by spaces, such as http_500 http_502, which supports the following policies:
  • error: fail to establish a connection and return directly
  • timeout: the connection times out and returns directly
  • invalid_response: invalid return status code and return directly
  • http_xxx: xxx can be replaced by a status code. For example, if it is set to http_500, it means that the next workload is selected when the upstream returns 500. The supported status codes include: 500, 502, 503, 504, 403, 404, 429
  • off: disable the retry mechanism, regardless of Any error returns directly
nginx.ingress.kubernetes.io/proxy-next-upstream-tries The number of retries available if the retry condition is met.
nginx.ingress.kubernetes.io/proxy-request-buffering Enable request buffering. Set to on to enable request buffering, off to disable a request buffering. If enabled, full request data is received before being forwarded to the backend workload, otherwise requests may be forwarded when partial request data is received. HTTP/1.1 Chunked encoded requests are not limited by this parameter and will always be buffered. If disabled, the next workload will not be selected for retry when a sending error occurs during sending.